On
No
HVBV-ATE 32 sites
High voltage breakdown tracer.
-
What it's for
The 32 sites system tests the robustness and breakdown curve of high voltage electronic semiconductors and components.
User-friendly software manages up to 32 sites allowing modular configuration.
-
Technical features
- INDIVIDUALLY PROGRAMMABLE PS-DUT 32CH:
- FROM 50V TO 2.000VDC (STEP 100MV, 0.5% ACCURACY)
- 4 RANGES FOR CURRENT MEASUREMENT:
- 5uA - ACCURACY 15nA
- 50uA - ACCURACY 150nA
- 5mA - ACCURACY 15uA
- 50mA - ACCURACY 150uA
- 16 SINGLE MODULES ON EACH DRAWER
- EASY TO USE GUI SOFTWARE INTERFACE FOR:
- PROGRAMMING AND CONFIGURATIONS CONTROL
- TEST SEQUENCE EXECUTION
- SYSTEM MONITORING
- DATA STORAGE AND TEST RESULT REPORT
- REMOTE CONTROL THROUGH LAN CONNECTION
- POWER DISTRIBUTION UNIT (PDU) TO ISOLATE, DISTRIBUTE AND SAFELY
- MANAGE MAINS AC VOLTAGE
- FULLY INDEPENDENT AND DIFFERENT TEST PROGRAM CAN RUN SEPARATELY ON EACH MODULE AT SAME TIME
- REMOTE CONNECTION FUNCTION THROUGH, WEB BROWSER, SMARTPHONE AND TABLET
- SMS ALERT OPTION
- INDIVIDUALLY PROGRAMMABLE PS-DUT 32CH:
Key features
HIGH VOLTAGE, HIGH ACCURACY TEST SYSTEM DESIGNED FOR DEVICE QUALIFICATION, CHARACTERIZATION, HTRB, BURN-IN, OLT.